Avoids the need for reinforcement.
Ideal for use with underfloor heating systems enabling rapid commissioning of the underfloor heating in accordance with BS1264:2001-Part 4 clause 4.4.
Significantly reduced thickness when compared to traditional sand - cement screed.
Weight saving as a result of thinner section.
Large bay sizes of up to 30-40 linear meters depending on application.
Dries at a rate of 1mm per day up to a screed depth of 40mm however this can be affected by adverse site conditions.
Can be force dried as early as 7 days after application.
Easily achieves SR2 finish as described in BS8204.
Protein free - cannot harbour harmful bacteria.
Non combustible (tested to BS476 Part 4).
Minimal Thermal expansion (0.012mm/mK).
Excellent thermal conductivity (2.2W/mK).
Self compacting.